Comfort System (CS)
CCE CS
There are many different skillsets in the life of a field technician — engineering, IT infrastructure, technical support, and computer programming, to name a few. CS training will prepare field technicians to confidently install, commission, troubleshoot, and edit an i-Vu system utilizing Field Assistant. This course is designed to develop an efficient field technician for a job site right away.
duration | cost | format |
---|---|---|
4 days | $1250 | classroom |
There are many different skillsets in the life of a field technician — engineering, IT infrastructure, technical support, and computer programming, to name a few. CS training will prepare field technicians to confidently install, commission, troubleshoot, and edit an i-Vu system utilizing Field Assistant. This course is designed to develop an efficient field technician for a job site right away.
For more information on the Carrier Controls Expert Program, please contact your local Carrier Controls sales representative or visit carrier.com/controls-experts.
Who should attend this training
The CS course has been developed for Carrier Field Office field technicians/engineers who are new to the Carrier i-Vu Tools hardware and software.
Learning Objectives
At the conclusion of this course, each student should be able to:
- Install and proficiently use the i-Vu Tech Tool Suite
- Perform essential system and network troubleshooting
- Wire and configure a VVT system
- Wire and configure a VAV system
Training Methods Used
This course is instructor-led in a classroom setting with extensive hands-on tasks to present the material. Student’s achievement of the learning objectives is determined by successful completion of the course and final exam.
Topics Covered
Local Networks
- Check 7 Different Control Modules
- Communications Check
- Device Instance
i-Vu® Tech tools Installation
- Install i-Vu® Tools
- Save a Copy of the Resources Folder
- Login to HVACPartners.com
Configure a Router/Link
- Preparing the IP connection for the Computer (DHCP)
- Preparing the Router for Communication
- setup/Check the Local Network Ports
Laptop Setup and Field Assistant® Update
- Preparing the Computer for Communications
- Prepare the Cumulative Patch
- Install the Latest Cumulative patch
- Create a System
Field Assistant®, Preparing a New Site
- Prepare for Communication
- Launch Field Assistant®
- Find Devices
Field Assistant® Site Setup
- Time Broadcasting
- Graphic Interface
- Scheduling
- Trends
- Reports
- Global Modify
Optimizing Downloads
▪ Determine Marker or Full Source Downloads
Exporting Source Files
AppLoader
- Clip the AppController
EquipmentBuilder®
- Prepare the new sal files for use
- Create a New Folder
- Create Equipment
- Select the Files to Generate
- Select the Location to Save the Files
Add a Control Program
Commission the Program
- Configure Hardware Inputs and Outputs
RTU Open lab
- Configure RTU Open ▪ Change/Lock Values for simulation
RTU Open Setup for use in a VVT Zoning system
- Adjust PID Loops for VVT Zoning System
- Search for econ_pid-da
- Search for clg_pid_da
- Search for htg_pid_ra
VVT Bypass Lab
- Configure VVT Bypass Controller
- Test and Balance
VVT Terminal Unit lab
- Configure a VVT Zone Controller
- Test and Balance
VVT Master Terminal Unit lab
- Release VVT Airside Linkage
- Configure VAV Airside Linkage
- Verify Linkage is Active
- RTU Open, Verify Linkage
Build a VVT Control System
- Use the Building Layout
- Create a Carrier Material List
- Draw out the Network
- Addresses
- Breakout into Groups, Build a system on together
Air Source (AppController)
- Configure the I/O Channels
- Scheduling
- Checkout Notes and Reports
VAVB1 Zone Terminal lab
- VAVB1 Configuration
- Test and Balance
- Activate the ZS Sensor
VAVB3 Zone Terminal Unit lab
- VAVB3 Configuration
- Test and Balance
VAV Master Terminal Unit lab
- Configure VAV Airside Linkage
- Setup a Rogue Zone
- Verify Linkage is Working
- Single Point Linkage
VAV Test and Balance
- Connect Test and Balance Tool
- Running Test and Balance
- Clear Parameter Mismatches in Field Assistant®
System Touch
- Access the System Touch Setup Menu
- Change the Admin Password
- Configure Sensor Setup
- Configure Inactivity Timeout
- Discover Control Modules
- Create Group Schedules
Equipment Touch
- Attach to an Open Controller from the System Touch
- View Alarm Sources
- View Schedules
- View Trends
- Equipment Properties Menu
- View Active Alarm Buffer
Factory Reset
- Default settings
Materials Needed
Student will need an account in HVACpartners prior to the class start date. Please contact your local Carrier Sales Office to create.
Class hours
Classes run 8am-5pm EDT.
Location & lodging
Kennesaw, Georgia, unless noted otherwise. An email with directions to the facility and lodging information will be provided once the class is confirmed, approximately 3 weeks prior to start date.
There are many different skillsets in the life of a field technician — engineering, IT infrastructure, technical support, and computer programming, to name a few. CS training will prepare field technicians to confidently install, commission, troubleshoot, and edit an i-Vu system utilizing Field Assistant. This course is designed to develop an efficient field technician for a job site right away.
For more information on the Carrier Controls Expert Program, please contact your local Carrier Controls sales representative or visit carrier.com/controls-experts.
Who should attend this training
The CS course has been developed for Carrier Field Office field technicians/engineers who are new to the Carrier i-Vu Tools hardware and software.
Learning Objectives
At the conclusion of this course, each student should be able to:
- Install and proficiently use the i-Vu Tech Tool Suite
- Perform essential system and network troubleshooting
- Wire and configure a VVT system
- Wire and configure a VAV system
Training Methods Used
This course is instructor-led in a classroom setting with extensive hands-on tasks to present the material. Student’s achievement of the learning objectives is determined by successful completion of the course and final exam.
Topics Covered
Local Networks
- Check 7 Different Control Modules
- Communications Check
- Device Instance
i-Vu® Tech tools Installation
- Install i-Vu® Tools
- Save a Copy of the Resources Folder
- Login to HVACPartners.com
Configure a Router/Link
- Preparing the IP connection for the Computer (DHCP)
- Preparing the Router for Communication
- setup/Check the Local Network Ports
Laptop Setup and Field Assistant® Update
- Preparing the Computer for Communications
- Prepare the Cumulative Patch
- Install the Latest Cumulative patch
- Create a System
Field Assistant®, Preparing a New Site
- Prepare for Communication
- Launch Field Assistant®
- Find Devices
Field Assistant® Site Setup
- Time Broadcasting
- Graphic Interface
- Scheduling
- Trends
- Reports
- Global Modify
Optimizing Downloads
▪ Determine Marker or Full Source Downloads
Exporting Source Files
AppLoader
- Clip the AppController
EquipmentBuilder®
- Prepare the new sal files for use
- Create a New Folder
- Create Equipment
- Select the Files to Generate
- Select the Location to Save the Files
Add a Control Program
Commission the Program
- Configure Hardware Inputs and Outputs
RTU Open lab
- Configure RTU Open ▪ Change/Lock Values for simulation
RTU Open Setup for use in a VVT Zoning system
- Adjust PID Loops for VVT Zoning System
- Search for econ_pid-da
- Search for clg_pid_da
- Search for htg_pid_ra
VVT Bypass Lab
- Configure VVT Bypass Controller
- Test and Balance
VVT Terminal Unit lab
- Configure a VVT Zone Controller
- Test and Balance
VVT Master Terminal Unit lab
- Release VVT Airside Linkage
- Configure VAV Airside Linkage
- Verify Linkage is Active
- RTU Open, Verify Linkage
Build a VVT Control System
- Use the Building Layout
- Create a Carrier Material List
- Draw out the Network
- Addresses
- Breakout into Groups, Build a system on together
Air Source (AppController)
- Configure the I/O Channels
- Scheduling
- Checkout Notes and Reports
VAVB1 Zone Terminal lab
- VAVB1 Configuration
- Test and Balance
- Activate the ZS Sensor
VAVB3 Zone Terminal Unit lab
- VAVB3 Configuration
- Test and Balance
VAV Master Terminal Unit lab
- Configure VAV Airside Linkage
- Setup a Rogue Zone
- Verify Linkage is Working
- Single Point Linkage
VAV Test and Balance
- Connect Test and Balance Tool
- Running Test and Balance
- Clear Parameter Mismatches in Field Assistant®
System Touch
- Access the System Touch Setup Menu
- Change the Admin Password
- Configure Sensor Setup
- Configure Inactivity Timeout
- Discover Control Modules
- Create Group Schedules
Equipment Touch
- Attach to an Open Controller from the System Touch
- View Alarm Sources
- View Schedules
- View Trends
- Equipment Properties Menu
- View Active Alarm Buffer
Factory Reset
- Default settings
Materials Needed
Student will need an account in HVACpartners prior to the class start date. Please contact your local Carrier Sales Office to create.
Class hours
Classes run 8am-5pm EDT.
Location & lodging
Kennesaw, Georgia, unless noted otherwise. An email with directions to the facility and lodging information will be provided once the class is confirmed, approximately 3 weeks prior to start date.