42TW/MW
Chilled-Water Low-Height Fan Coil
300 to 2000 Nominal Cfm
The 42TW/MW standard cooling low height chilled water fan coil units are available in airflow range from 300 Cfm to 2000 Cfm. All series are available with a 3 or 4 row coil.
Each unit is designed to occupy a minimum space. Piping and drain connections are readily accessible and mounting holes and slots are pre-drilled to save installation time and field labor expense.
42TW Series are available in 8 sizes designed for medium external static pressure up to 0.25 inches water (63 Pa) in low false ceiling applications with nominal cooling capacity from 12 to 60 KBtu/Hr.
42MW Series are available in 2 sizes designed for high external static pressure up to 0.5 inches water (125 Pa) in low false ceiling applications with nominal cooling capacity from 48 to 60 KBtu/Hr.
Performance Features
- Airflow ranges from 300 to 2000 Cfm
- TW - Standard Cooling Low Static.
- MW - Standard Cooling High Static.
- Low unit height suitable for low false ceiling application
- 42TW3 (275mm upto size 11 and 375mm for size 12 and 16)
- 42TW4 (275mm upto size 10 and 375mm for size 11 and 14)
- 42MW (375mm all sizes)
- 3-speed high efficiency motor with B class insulation
- Standard galvanized sheet metal casing
- 10 mm thickness internal insulation with 32 kg/m^3 density
- Low noise level suitable for all application
- Plastic blower and blower housing
- Sweat connections for easy installation and maintenance
- Electrical intigrated wired control board and thermostat with remote control as a standard feature
- Single point electrical connection
- Units are rated in accordance with ARI standard
- Units have external drain pan with 10 mm insulation, the drain pan is be painted steel withstanding ASTM (American Society for Testing and Materials) B117 500 hour Salt Spray Test.
- Piping connection are field exchangeable; Standard right hand side
Options
- Left hand connection option is available
- Washable aluminum filter
- Factory installed heater option
- Remote mounted thermostats
- UVC
Performance Features
- Airflow ranges from 300 to 2000 Cfm
- TW - Standard Cooling Low Static.
- MW - Standard Cooling High Static.
- Low unit height suitable for low false ceiling application
- 42TW3 (275mm upto size 11 and 375mm for size 12 and 16)
- 42TW4 (275mm upto size 10 and 375mm for size 11 and 14)
- 42MW (375mm all sizes)
- 3-speed high efficiency motor with B class insulation
- Standard galvanized sheet metal casing
- 10 mm thickness internal insulation with 32 kg/m^3 density
- Low noise level suitable for all application
- Plastic blower and blower housing
- Sweat connections for easy installation and maintenance
- Electrical intigrated wired control board and thermostat with remote control as a standard feature
- Single point electrical connection
- Units are rated in accordance with ARI standard
- Units have external drain pan with 10 mm insulation, the drain pan is be painted steel withstanding ASTM (American Society for Testing and Materials) B117 500 hour Salt Spray Test.
- Piping connection are field exchangeable; Standard right hand side
Options
- Left hand connection option is available
- Washable aluminum filter
- Factory installed heater option
- Remote mounted thermostats
- UVC