AquaForce®
30XW/ XW-P
High-Efficiency Water-Cooled Screw Chiller
With R-134a Refrigerant
Cooling capacity: 250~1776 kW
- Reliable screw compressor
- Compact foot print
- Auto adaptive control
- Quick & easy installation
- Safe operation
- Exceptional endurance test
- Economizer system
- Efficient heat exchanger
- Multiple circuit design
- Environmentally sustainable
Reliable Screw Compressor
- Carrier’s own ‘06T’ semi-hermetic screw compressor
- with direct driven motor
- Variable capacity slide valve
- Oversized bearing and suction gas cooled motor
- All components are easily accessible on site – minimized down time
- Patented line-design rotors and microprocessor control – guaranted accurate refrigerant meshing & enhanced service life
Compact Foot Print
- 1.0 m ~ 1.2 m width – easy through standard doorway
- Saves plant room space – reduces investment
- Best choice for new construction and retrofit projects
Auto Adaptive Control
- Automatic compressor unloading in case of abnormally high condensing pressure
- Patented control algorithm preventing excessive compressor cycling
Quick & Easy Installation
- Simplified electrical connection
- Main disconnect switch with high trip capacity
- Transformer to supply integrated control circuit
- Simplified hydronic connection
- Victaulic connection on evaporator & condenser
- 2 pass design – Inlet/Outlet on same side
- Only electrical wiring & piping connection needed at site
Safe Operation
- Reversal/phase loosing protection
- Compressor protected against thermal overload, high pressure and low oil pressure
- Automatic compressor unloading in case of excessing condensing temperature
- Protection against current imbalance and electrical overload
- Low chilled water temperature protection
Exceptional Endurance Test
- Partnerships with specialised laboratories and use of limit simulation tools (finite element calculation) for the design of critical components
- Transport simulation test in the laboratory on a vibrating table and then on endurance circuit
Economizer System
- Economizer system with EXV permits considerable increase in cooling capacity and contributes to optimized efficiency
- Electronic expansion valve (EXV) allows operation at lower condensing pressure and improved utilization of evaporator heat exchange surface (superheat control)
Efficient Heat Exchanger
- High efficiency flooded evaporator
- Inbuilt electronic flow switch
- Auto setting basis cooler size and fluid type
Multiple Circuit Design
- Independent refrigerant circuits
- Independent electrical circuits
Environmentally Sustainable
- HFC-134a refrigerant
- Refrigerant of the HFC group with zero ozone depletion potential
- Leak-tight refrigerant circuit
- Reduction of leaks as no capillary tubes and flare connections are used
- Verification of pressure transducers and temperature sensors without transferring refrigerant charge
Reliable Screw Compressor
- Carrier’s own ‘06T’ semi-hermetic screw compressor
- with direct driven motor
- Variable capacity slide valve
- Oversized bearing and suction gas cooled motor
- All components are easily accessible on site – minimized down time
- Patented line-design rotors and microprocessor control – guaranted accurate refrigerant meshing & enhanced service life
Compact Foot Print
- 1.0 m ~ 1.2 m width – easy through standard doorway
- Saves plant room space – reduces investment
- Best choice for new construction and retrofit projects
Auto Adaptive Control
- Automatic compressor unloading in case of abnormally high condensing pressure
- Patented control algorithm preventing excessive compressor cycling
Quick & Easy Installation
- Simplified electrical connection
- Main disconnect switch with high trip capacity
- Transformer to supply integrated control circuit
- Simplified hydronic connection
- Victaulic connection on evaporator & condenser
- 2 pass design – Inlet/Outlet on same side
- Only electrical wiring & piping connection needed at site
Safe Operation
- Reversal/phase loosing protection
- Compressor protected against thermal overload, high pressure and low oil pressure
- Automatic compressor unloading in case of excessing condensing temperature
- Protection against current imbalance and electrical overload
- Low chilled water temperature protection
Exceptional Endurance Test
- Partnerships with specialised laboratories and use of limit simulation tools (finite element calculation) for the design of critical components
- Transport simulation test in the laboratory on a vibrating table and then on endurance circuit
Economizer System
- Economizer system with EXV permits considerable increase in cooling capacity and contributes to optimized efficiency
- Electronic expansion valve (EXV) allows operation at lower condensing pressure and improved utilization of evaporator heat exchange surface (superheat control)
Efficient Heat Exchanger
- High efficiency flooded evaporator
- Inbuilt electronic flow switch
- Auto setting basis cooler size and fluid type
Multiple Circuit Design
- Independent refrigerant circuits
- Independent electrical circuits
Environmentally Sustainable
- HFC-134a refrigerant
- Refrigerant of the HFC group with zero ozone depletion potential
- Leak-tight refrigerant circuit
- Reduction of leaks as no capillary tubes and flare connections are used
- Verification of pressure transducers and temperature sensors without transferring refrigerant charge