Skip to main content

Desert Master™
50TCM

Single-Packaged Rooftop
Electric Cooling Units
Puron® (R-410A) Refrigerant

6.0 to 12.5 nominal tons

The 50TCM units are single side discharge rooftop cooling units utilizing electric heat as an option. Units are prewired, and pre-charged with R-410A refrigerant, and tested at the factory. These units can be placed on the side of a building or on a roof without roof curbs. Each unit is designed to occupy a minimal space, with piping and drain connections readily accessible.

Carrier’s Package Rooftop Unit software makes selecting and optimizing the 50TCM easy.

Key Features

  • Environment friendly refrigerant, R410A , Chlorine free HFC, ZERO ODP
  • ASHRAE 90.1 compliant
  • EER’s up to 12.50
  • TXV refrigerant metering device
  • Independent refrigerant circuits, each with a scroll compressor
  • Low outdoor temperature cooling operation down to 40°F
  • Cooling operating range up to 125 °F (51.6°C)
  • Liquid filter drier standard on each circuit
  • Fresh air intake capability
  • Non-corrosive sloped condensate drain pan in accordance to ASHRAE 62 standard
  • Thermally protected and permanently lubricated condenser and evaporator fan motors
  • Angle type return air section with washable type filters

Superior Reliability, Efficiency and Safety

  • Exceptional endurance tests:
    • Painted panels tested to ASTM B-117 500 hours salt spray protection
    • Pre-coated fin condenser coil for extra corrosion protection
  • Compressor protection:
    • High and low pressure cutouts
    • Phase protection relay
    • Crankcase heaters are standard for all units
    • Internal over temperature protection
    • Freeze protection
  • Low vibration design:
    • Leak-tight refrigerant circuit
    • Brazed refrigerant connections for increased leak tightness
    • Low-noise scroll compressors with low vibration levels
  • Control circuit protected by circuit breaker
  • Thermally protected and permanently lubricated condenser and evaporator fan motors
  • Angle type return air section with washable type filters
  • Transformer for safe 24v control circuit supply included
  • High efficiency, High Static Blower
  • State-of-art scroll compressor technology
  • Dual, electrically and mechanically independent refrigerant circuit

Installation Features

  • Single point electrical service entry
  • Side discharge application
  • No roof curb needed
  • Side-by-side supply and return air
  • Separate panel for control box

Factory-Installed Options

  • Refrigerant sight glass - Installed on each circuit
  • Pre-coated fins - condenser only
  • Copper fins - condenser only
  • Copper fins - condenser and evaporator
  • Multiple motor and drive packages

Field-Installed Accessories

  • Electric resistance heater package
  • Single point kit
  • UVC ready
  • Softbag filters

Key Features

  • Environment friendly refrigerant, R410A , Chlorine free HFC, ZERO ODP
  • ASHRAE 90.1 compliant
  • EER’s up to 12.50
  • TXV refrigerant metering device
  • Independent refrigerant circuits, each with a scroll compressor
  • Low outdoor temperature cooling operation down to 40°F
  • Cooling operating range up to 125 °F (51.6°C)
  • Liquid filter drier standard on each circuit
  • Fresh air intake capability
  • Non-corrosive sloped condensate drain pan in accordance to ASHRAE 62 standard
  • Thermally protected and permanently lubricated condenser and evaporator fan motors
  • Angle type return air section with washable type filters

Superior Reliability, Efficiency and Safety

  • Exceptional endurance tests:
    • Painted panels tested to ASTM B-117 500 hours salt spray protection
    • Pre-coated fin condenser coil for extra corrosion protection
  • Compressor protection:
    • High and low pressure cutouts
    • Phase protection relay
    • Crankcase heaters are standard for all units
    • Internal over temperature protection
    • Freeze protection
  • Low vibration design:
    • Leak-tight refrigerant circuit
    • Brazed refrigerant connections for increased leak tightness
    • Low-noise scroll compressors with low vibration levels
  • Control circuit protected by circuit breaker
  • Thermally protected and permanently lubricated condenser and evaporator fan motors
  • Angle type return air section with washable type filters
  • Transformer for safe 24v control circuit supply included
  • High efficiency, High Static Blower
  • State-of-art scroll compressor technology
  • Dual, electrically and mechanically independent refrigerant circuit

Installation Features

  • Single point electrical service entry
  • Side discharge application
  • No roof curb needed
  • Side-by-side supply and return air
  • Separate panel for control box

Factory-Installed Options

  • Refrigerant sight glass - Installed on each circuit
  • Pre-coated fins - condenser only
  • Copper fins - condenser only
  • Copper fins - condenser and evaporator
  • Multiple motor and drive packages

Field-Installed Accessories

  • Electric resistance heater package
  • Single point kit
  • UVC ready
  • Softbag filters