23XRV

175 to 550 Nominal Tons (615 to 1,934 kW)

The 23XRV chiller is the world’s first integrated variable-speed, water cooled, screw chiller. The 23XRV incorporates significant breakthroughs in water-cooled chiller technology to provide excellent reliability and achieve superior efficiency at true operating conditions without compromising the environment. Quality design and construction make the AquaEdge® 23XRV chillers the best choice for modern, efficient chilled water plants.

Carrier's AquaEdge chillers offer the best value in high-efficiency chlorine-free variable-speed screw HVAC chillers.

Quickly evaluate chiller system performance

Carrier’s PLV Pro is a software tool that empowers consulting engineers to make objective and informed decisions about their chiller plant design that go beyond Full Load and IPLV metrics. Results are provided in a professional report or .csv format for further analysis. The tool is for professionals who need a quick and free-of-charge alternative to detailed energy modeling analyses.

Learn More

Water-cooled chillers within the scope of the AHRI WCCL certification program are certified in accordance with the AHRI Water-Cooled Water-Chilling and Heat Pump Water-Heating Packages Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org.


carrier-AHRI-550-590-551-591_WCCL
carrier-seismic-compliant
carrier-iso-9001
carrier-c-ul-us

Performance Features

  • IPLV to 0.299
  • Chlorine-free HFC-134a or R-513A refrigerant
  • Full Load kW/Ton to 0.53
  • Tri-rotor, positive displacement screw compressor
  • Hermetic compressor motor
  • Refrigerant-cooled (Q & R compressors) or air-cooled (P compressor), unit-mounted variable frequency drive
  • Low inrush current
  • Operation of up to 0.99 power factor
  • Flooded evaporator
  • Float valve (Q & R compressor) or EXV (P compressor)
  • Superior oil management/cold condenser water operation
  • Internally and externally enhanced 0.025 in. (0.635 mm) copper tubing
  • 150 psig (1034 kPa) rated evaporator and condenser
  • SmartVu Touchscreen Control Display
  • Multilingual display
  • Demand limiting capability with Carrier Comfort Network® (CCN) communication link

Reliability Features

  • ASME constructed heat exchangers
  • Low voltage control circuits
  • Lowest industry refrigerant leakage rate at less than 0.1%
  • Hermetically sealed compressor motor
  • Automated controls may be tested before start-up
  • 65K AIC circuit breaker

Maintenance Features

  • Password protected extensive service menu with built-in diagnostic capabilities, troubleshooting, and corrective action recommendations for preset alarms
  • Alarm and alert files maintain the last 25 time and date stamped messages in memory
  • Configuration data backup with non-volatile memory
  • Refrigerant filter isolation valves
  • Thermistor type temperature sensor with quick connects in each water nozzle
  • Service contract available

Installation Features

  • Modular construction
  • Single point electrical connection
  • Can be dismantled and reassembled
  • Unit-mounted VFD with single point connection
  • Small footprint

Standard Warranty

  • One year from start-up or 18 months from shipment
  • Refrigerant warranty 5 years from date of manufacture (Domestic & Canada only)
  • Extended warranties available (Domestic & Canada only)

Factory-Installed Options

  • Enhanced tubing, .028 or .035 in. (0.711 or 0.889 mm):
    • Internally/externally enhanced copper tubing - evaporator/condenser
    • Internally/externally enhanced cupronickel tubing - condenser
    • Smooth bore/externally enhanced copper tubing - evaporator/condenser
    • Smooth bore/externally enhanced cupronickel tubing - condenser
  • Wall tubes, titanium, condenser, .025 or .028 in. (0.635 or 0.711 mm):
    • Internally enhanced tubes
    • Smooth bore tubes
  • Marine waterboxes (available for heat exchanger frames 3-5 only):
    • 150 psig (1034 kPa) waterbox
    • 300 psig (2068 kPa) waterbox
  • Nozzle-in-head waterbox, 300 psig (2068 kPa)
  • Hinged waterboxes
  • Flanged evaporator and/or condenser waterbox nozzles
  • One, 2, or 3 pass evaporator or condenser waterside construction
  • Zinc anodes
  • 100K AIC high interrupt circuit breaker with shunt trip
  • Analog voltmeter and ammeter with 3-phase selector switch
  • Shipped factory charged with refrigerant
  • Hot gas bypass
  • Full cold surface thermal insulation (except waterbox covers)
  • Customer factory performance testing
  • Export crating

Field-Installed Accessories

  • LonWorks® Carrier translator
  • Sensor package
  • Separate storage tank and pumpout unit
  • Stand-alone pumpout unit
  • Soleplate package
  • Spring isolator kit
  • Refrigerant isolation valves for in-chiller refrigerant storage
  • Unit-mounted pumpout unit for storing refrigerant inside the chiller during servicing
  • Shipped fully charged
Nominal Capacity (Tons)* Heat Exchanger Size Length with Nozzle-in-Head Waterbox Width Height
2-Pass** 1 or 3-Pass
ft-in mm ft-in mm ft-in mm ft-in mm
175-550 30 to 32 13-8¼ 4172 14-3¼ 4350 See Unit
Certified
Drawings
See Unit
Certified
Drawings
35 to 37 15-4¾ 4693 15-11¾ 4870
40 to 42, 4D 14-3⅛ 4347 14-9 4496
45 to 47, 4E 15-11⅝ 4867 16-5½ 5017
50 to 52 14-4½ 4382 14-10 4521
55 to 57 16-1 4902 16-6½ 5042
A 14-1¼ 4301 14-6¾ 4439
B 15-9¾ 4822 16-3¼ 4959

*For job specific dimensions and weight information, please contact your Carrier Sales Representative.

**Assumes all customer connections are on the same end of the chiller.

Performance Features

  • IPLV to 0.299
  • Chlorine-free HFC-134a or R-513A refrigerant
  • Full Load kW/Ton to 0.53
  • Tri-rotor, positive displacement screw compressor
  • Hermetic compressor motor
  • Refrigerant-cooled (Q & R compressors) or air-cooled (P compressor), unit-mounted variable frequency drive
  • Low inrush current
  • Operation of up to 0.99 power factor
  • Flooded evaporator
  • Float valve (Q & R compressor) or EXV (P compressor)
  • Superior oil management/cold condenser water operation
  • Internally and externally enhanced 0.025 in. (0.635 mm) copper tubing
  • 150 psig (1034 kPa) rated evaporator and condenser
  • SmartVu Touchscreen Control Display
  • Multilingual display
  • Demand limiting capability with Carrier Comfort Network® (CCN) communication link

Reliability Features

  • ASME constructed heat exchangers
  • Low voltage control circuits
  • Lowest industry refrigerant leakage rate at less than 0.1%
  • Hermetically sealed compressor motor
  • Automated controls may be tested before start-up
  • 65K AIC circuit breaker

Maintenance Features

  • Password protected extensive service menu with built-in diagnostic capabilities, troubleshooting, and corrective action recommendations for preset alarms
  • Alarm and alert files maintain the last 25 time and date stamped messages in memory
  • Configuration data backup with non-volatile memory
  • Refrigerant filter isolation valves
  • Thermistor type temperature sensor with quick connects in each water nozzle
  • Service contract available

Installation Features

  • Modular construction
  • Single point electrical connection
  • Can be dismantled and reassembled
  • Unit-mounted VFD with single point connection
  • Small footprint

Standard Warranty

  • One year from start-up or 18 months from shipment
  • Refrigerant warranty 5 years from date of manufacture (Domestic & Canada only)
  • Extended warranties available (Domestic & Canada only)

Factory-Installed Options

  • Enhanced tubing, .028 or .035 in. (0.711 or 0.889 mm):
    • Internally/externally enhanced copper tubing - evaporator/condenser
    • Internally/externally enhanced cupronickel tubing - condenser
    • Smooth bore/externally enhanced copper tubing - evaporator/condenser
    • Smooth bore/externally enhanced cupronickel tubing - condenser
  • Wall tubes, titanium, condenser, .025 or .028 in. (0.635 or 0.711 mm):
    • Internally enhanced tubes
    • Smooth bore tubes
  • Marine waterboxes (available for heat exchanger frames 3-5 only):
    • 150 psig (1034 kPa) waterbox
    • 300 psig (2068 kPa) waterbox
  • Nozzle-in-head waterbox, 300 psig (2068 kPa)
  • Hinged waterboxes
  • Flanged evaporator and/or condenser waterbox nozzles
  • One, 2, or 3 pass evaporator or condenser waterside construction
  • Zinc anodes
  • 100K AIC high interrupt circuit breaker with shunt trip
  • Analog voltmeter and ammeter with 3-phase selector switch
  • Shipped factory charged with refrigerant
  • Hot gas bypass
  • Full cold surface thermal insulation (except waterbox covers)
  • Customer factory performance testing
  • Export crating

Field-Installed Accessories

  • LonWorks® Carrier translator
  • Sensor package
  • Separate storage tank and pumpout unit
  • Stand-alone pumpout unit
  • Soleplate package
  • Spring isolator kit
  • Refrigerant isolation valves for in-chiller refrigerant storage
  • Unit-mounted pumpout unit for storing refrigerant inside the chiller during servicing
  • Shipped fully charged
Nominal Capacity (Tons)* Heat Exchanger Size Length with Nozzle-in-Head Waterbox Width Height
2-Pass** 1 or 3-Pass
ft-in mm ft-in mm ft-in mm ft-in mm
175-550 30 to 32 13-8¼ 4172 14-3¼ 4350 See Unit
Certified
Drawings
See Unit
Certified
Drawings
35 to 37 15-4¾ 4693 15-11¾ 4870
40 to 42, 4D 14-3⅛ 4347 14-9 4496
45 to 47, 4E 15-11⅝ 4867 16-5½ 5017
50 to 52 14-4½ 4382 14-10 4521
55 to 57 16-1 4902 16-6½ 5042
A 14-1¼ 4301 14-6¾ 4439
B 15-9¾ 4822 16-3¼ 4959

*For job specific dimensions and weight information, please contact your Carrier Sales Representative.

**Assumes all customer connections are on the same end of the chiller.

carrier-gsa-proving-ground-report-cover-on-blue-green-background-card
Variable Speed Screw Technology raises the bar on chiller performance
carrier-23xrv-gpg-title-card
GSA Proving Ground Program
carrier-23xrv-iplv-jet-in-clouds
The Optimal Chiller Solution
carrier-exterior-educational-bldg
Expert Training @ Carrier University: 23XRV Liquid Screw Chiller Service & Operator