i-Vu® VAV Zone II Secondary Terminal
OPN-SECTRM-02
Product Integrated Controller
The VAV Zone II Secondary Terminal controller provides control of a secondary zone damper where CFM measurement is required. This advanced controller features a separable actuator for easy installation onto a zone damper. It requires connection to the programmable Carrier Zone Controller (OPN-B3-P-02) for proper operation.
Application Features
- Dual Duct - Hot Deck/Cold Deck control
- DOAS applications
- Quick and easy test & balancing process
System Benefits
- Fully plug-and-play with the Carrier i-Vu Building Automation System
- Connects directly to the ACTnet bus on Carrier ZoneCtrl II programmable zone controller
Hardware Features
- Separate brushless actuator for reliability and longevity
- ACTnet communications bus
- Precision differential pressure sensor
Communication Ports | ACTnet Port: For connecting the actuator cable and to the ZoneCtrl II |
Separable Actuator | Brushless DC motor, torque 45 inch-pounds (5Nm), runtime 205 seconds for 90 degree travel during control. |
Integral Pressure Sensor | Precision low flow AWM series O-2 in H2O, sensitive down to +/-0.001 in. H2O. Barbed tapered airflow connections accept 3/16 in. (4.75 mm) ID tubing. Allows for readings across the 0-2 in H2O range, accurate to +/-5% of full flow at 2 in. H2O. |
Protection | Incoming power and network connections are protected by non-replaceable internal solid state polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input and output connections are also protected against voltage transient and surge events. |
Status Indicators | LED status indicators for run status, error, power and motor direction |
Listed by | UL-916 (PAZX), cUL-916 (PAZX7), FCC Part 15-Subpart B-Class A, CE EN50082-1997, Fire-retardant plastic ABS, UL94-5VA |
Environmental Operating Range | Operating: 32° to 130°F (0° to 54°C) 10 to 90% RH, non-condensing
Storage: -24° to 140°F (-30° to 60°C) 10 to 90% RH, non-condensing |
Power Requirements | 24VAC +/- 10%, 50-60Hz, 14 VA power consumption, 26VDC (25V min, 30V max), single class 2 source only, 100 VA or less |
Application Features
- Dual Duct - Hot Deck/Cold Deck control
- DOAS applications
- Quick and easy test & balancing process
System Benefits
- Fully plug-and-play with the Carrier i-Vu Building Automation System
- Connects directly to the ACTnet bus on Carrier ZoneCtrl II programmable zone controller
Hardware Features
- Separate brushless actuator for reliability and longevity
- ACTnet communications bus
- Precision differential pressure sensor
Communication Ports | ACTnet Port: For connecting the actuator cable and to the ZoneCtrl II |
Separable Actuator | Brushless DC motor, torque 45 inch-pounds (5Nm), runtime 205 seconds for 90 degree travel during control. |
Integral Pressure Sensor | Precision low flow AWM series O-2 in H2O, sensitive down to +/-0.001 in. H2O. Barbed tapered airflow connections accept 3/16 in. (4.75 mm) ID tubing. Allows for readings across the 0-2 in H2O range, accurate to +/-5% of full flow at 2 in. H2O. |
Protection | Incoming power and network connections are protected by non-replaceable internal solid state polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input and output connections are also protected against voltage transient and surge events. |
Status Indicators | LED status indicators for run status, error, power and motor direction |
Listed by | UL-916 (PAZX), cUL-916 (PAZX7), FCC Part 15-Subpart B-Class A, CE EN50082-1997, Fire-retardant plastic ABS, UL94-5VA |
Environmental Operating Range | Operating: 32° to 130°F (0° to 54°C) 10 to 90% RH, non-condensing
Storage: -24° to 140°F (-30° to 60°C) 10 to 90% RH, non-condensing |
Power Requirements | 24VAC +/- 10%, 50-60Hz, 14 VA power consumption, 26VDC (25V min, 30V max), single class 2 source only, 100 VA or less |
California residents please see Proposition 65