TruVu™ Compact Link
TV-CLB-E2

Network & Integration Device

The TruVu Compact Link is a router and gateway in one. It features dual IP ports for convenient daisy-chain deployment and offers robust routing capabilities between BACnet®/IP, BACnet Ethernet, and BACnet MS/TP networks, while also supporting BACnet and Modbus integration to third party devices.


carrier-bacnet-testing-laboratories

Link Features

  • BACnet Testing Laboratories (BTL) certified
  • Conforms to BACnet Router (B-RTR), and BACnet BBMD (B-BBMD) standard device profiles 
  • Supports BACnet routing between BACnet/IP, BACnet/Ethernet and BACnet/MSTP networks 
  • Can serve as the BACnet Broadcast Management Device (BBMD) 
  • Supports Modbus RTU and Modbus IP 
  • Supports up to 1,500 third-party BACnet points and up to 500 Modbus points (IP or Modbus RTU) 
  • Supports BACnet Foreign Device Registration (FDR) 
  • Supports SNAP graphical programs to create custom sequences

Hardware Features

  • IPv4 networks are supported 
  • Two 10/100 Mbps Ethernet Ports with fail-safe relay 
  • One isolated MS/TP Port, supporting speeds from 9.6 to 115.2 Kbps 
  • USB service port for local service: connect PC via a hard-wired connection or wirelessly using a USB-W adapter 
  • Compact footprint simplifies installation and optimizes panel space

System Benefits

  • Connects seamlessly to the i-Vu building automation system
BACnet Support Conforms to the BACnet Building Controller (B-BC), BACnet Router (B-RTR), and BACnet Broadcast Management Device (B-BBMD) Standard Device Profile as defined in ANSI/ASHRAE Standard 135-2012 (BACnet) Annex L, Protocol Revision 15
Power Requirements 24VAC ± 10%, 50-60Hz, 50 VA
24VDC ± 10%, 18W
Communication Ports Max Integration Points: Supports 1,500 BACnet points and 500 Modbus points (IP or Modbus RTU)
Eth0,Eth1: 10/100 BaseT, full duplex, Ethernet ports with built-in fail safe. Supports direct connection or daisy chain topology natively using BACnet/IP and/or BACnet Ethernet, or Modbus TCP/IP communication.
Port S1: For communication with a BACnet MS/TP network at 9600 to 115200 bps or with a Modbus serial network at 9600 to 115200 bps.
Port S2: For communication with a BACnet MS/TP network at 9600 to 115200 bps or with a Modbus serial network at 9600 to 115200 bps.
End of Net: Switch can be turned on to terminate the network segment.
Rnet: Supports up to 15 ZS sensors and one Equipment Touch or TruVu™ Equipment Touch.; Supplies 12 VDC/260 mA power to the Rnet across its rated temperature range.
Service Port: USB 2.0 host port for setting up the controller and troubleshooting through a local connection to a computer, connecting to the TruVu™ Equipment Touch, or the Carrier USB Wireless service adapter.
Protection Device is protected by a replaceable, fast acting, 250Vac, 3A, 5mm x 20mm glass fuse. The power and network ports comply with the EMC requirements EN50491-5-2.
Real-Time Clock Real-time clock keeps track of time in the event of a power failure for up to 3 days.
LED Status Indicators Tricolor NET LED to show network status / Tricolor SYS LED to show system status/POWER LED/S1 EON LED/A TX (Transmit) and RX (Receive) LED for: Port S1 & S2
Environmental Operating Range 40 to 158°F (-40 to 70°C), 10-95% relative humidity, non-condensing
The TV-CLB-E2 is suitable for installation inside or outside the building envelope. It should be placed in a UL Listed enclosure. If installed outside, the enclosure must be suitable for the environmental conditions.
Compliance United States of America: FCC compliant to Title CFR47, Chapter 1, Subchapter A, Part 15, Subpart B, Class A; UL Listed to UL 916, PAZX, Energy Management Equipment; Canada: Industry Canada Compliant, ICES-003, Class A cUL Listed UL 916, PAZX7, Energy Management Equipment; EN50491-5-2:2009; Part 5-2: EMC requirements for HBES/BACS used in residential, commercial and light industry environment RoHS Compliant: 2015/863/EU REACH Compliant; Australia and New Zealand: C-Tick Mark, AS/NZS 61000-6-3
Physical Fire-retardant plastic ABS, UL94-5VA
Mounting 35mm DIN rail mounting or screw mounting

Link Features

  • BACnet Testing Laboratories (BTL) certified
  • Conforms to BACnet Router (B-RTR), and BACnet BBMD (B-BBMD) standard device profiles 
  • Supports BACnet routing between BACnet/IP, BACnet/Ethernet and BACnet/MSTP networks 
  • Can serve as the BACnet Broadcast Management Device (BBMD) 
  • Supports Modbus RTU and Modbus IP 
  • Supports up to 1,500 third-party BACnet points and up to 500 Modbus points (IP or Modbus RTU) 
  • Supports BACnet Foreign Device Registration (FDR) 
  • Supports SNAP graphical programs to create custom sequences

Hardware Features

  • IPv4 networks are supported 
  • Two 10/100 Mbps Ethernet Ports with fail-safe relay 
  • One isolated MS/TP Port, supporting speeds from 9.6 to 115.2 Kbps 
  • USB service port for local service: connect PC via a hard-wired connection or wirelessly using a USB-W adapter 
  • Compact footprint simplifies installation and optimizes panel space

System Benefits

  • Connects seamlessly to the i-Vu building automation system
BACnet Support Conforms to the BACnet Building Controller (B-BC), BACnet Router (B-RTR), and BACnet Broadcast Management Device (B-BBMD) Standard Device Profile as defined in ANSI/ASHRAE Standard 135-2012 (BACnet) Annex L, Protocol Revision 15
Power Requirements 24VAC ± 10%, 50-60Hz, 50 VA
24VDC ± 10%, 18W
Communication Ports Max Integration Points: Supports 1,500 BACnet points and 500 Modbus points (IP or Modbus RTU)
Eth0,Eth1: 10/100 BaseT, full duplex, Ethernet ports with built-in fail safe. Supports direct connection or daisy chain topology natively using BACnet/IP and/or BACnet Ethernet, or Modbus TCP/IP communication.
Port S1: For communication with a BACnet MS/TP network at 9600 to 115200 bps or with a Modbus serial network at 9600 to 115200 bps.
Port S2: For communication with a BACnet MS/TP network at 9600 to 115200 bps or with a Modbus serial network at 9600 to 115200 bps.
End of Net: Switch can be turned on to terminate the network segment.
Rnet: Supports up to 15 ZS sensors and one Equipment Touch or TruVu™ Equipment Touch.; Supplies 12 VDC/260 mA power to the Rnet across its rated temperature range.
Service Port: USB 2.0 host port for setting up the controller and troubleshooting through a local connection to a computer, connecting to the TruVu™ Equipment Touch, or the Carrier USB Wireless service adapter.
Protection Device is protected by a replaceable, fast acting, 250Vac, 3A, 5mm x 20mm glass fuse. The power and network ports comply with the EMC requirements EN50491-5-2.
Real-Time Clock Real-time clock keeps track of time in the event of a power failure for up to 3 days.
LED Status Indicators Tricolor NET LED to show network status / Tricolor SYS LED to show system status/POWER LED/S1 EON LED/A TX (Transmit) and RX (Receive) LED for: Port S1 & S2
Environmental Operating Range 40 to 158°F (-40 to 70°C), 10-95% relative humidity, non-condensing
The TV-CLB-E2 is suitable for installation inside or outside the building envelope. It should be placed in a UL Listed enclosure. If installed outside, the enclosure must be suitable for the environmental conditions.
Compliance United States of America: FCC compliant to Title CFR47, Chapter 1, Subchapter A, Part 15, Subpart B, Class A; UL Listed to UL 916, PAZX, Energy Management Equipment; Canada: Industry Canada Compliant, ICES-003, Class A cUL Listed UL 916, PAZX7, Energy Management Equipment; EN50491-5-2:2009; Part 5-2: EMC requirements for HBES/BACS used in residential, commercial and light industry environment RoHS Compliant: 2015/863/EU REACH Compliant; Australia and New Zealand: C-Tick Mark, AS/NZS 61000-6-3
Physical Fire-retardant plastic ABS, UL94-5VA
Mounting 35mm DIN rail mounting or screw mounting