TB-TM

The Carrier TB and TM Series Thermostats available in BACnet (TB series) or MODBUS (TM series) communication protocols come with a variety of options and features for a wide range of HVAC applications. The TB and TM Series thermostats offer either zone/room/building control or building management system (BMS) level control. Utilizing Carrier’s powerful i-Vu® building automation system’s platform, the user can be sure that each space has precision temperature control.

  • Built-in temperature, humidity, and/or motion sensing for optimal control
  • Intuitive push-button interface with a clear LCD display
  • BACnet or MODBUS communication protocol capable (depending on model) for flexible system integration
  • Configurable inputs and outputs to support a variety of HVAC applications 
  • Real-time clock maintains accurate time for up to 7 days during power outages
  • Choice of 24VAC or 110-220V power supply for installation flexibility*

*Depending on thermostat model

  • Fan (FCUs): Enhance occupant comfort by providing individual control over fan speed and temperature
  • Rooftop Units (RTUs): Optimize RTU operation for energy efficiency through precise temperature and airflow control
  • Heat Pumps: Maximize heat pump performance and efficiency with integrated control of heating and cooling modes
  • Variable Frequency Drives (VFDs): Seamlessly integrate with VFDs to fine-tune motor speeds and optimize energy consumption

TB Series (BACnet)

Options 24 V, Temp. Only 24 V, Temp, Humidity, Motion 110-220V, Temp. Only
Branded TB-24-C TB-24-HM-C TB-C
Unbranded TB-24 TB-24-HM TB
Communication BACnet MS/TP (subordinate device) | Baud rates up to 76.8 kbps, detected and set automatically by the thermostat

TM Series (Modbus)

     
Options 24V, Temp., Humidity - 110 - 220V, Temp. Only
Unbranded TM-24 - TM
Communications Modbus RTU (server) | Baud rates up to 76.8 kbps, detected and set automatically by the thermostat
Power Requirements 24 VAC ± 15% 4VA no load, 76 VA Full Load 110-220 VAC
Display LCD
SENSING ELEMENT      
Temperature Range: 41-95° (5-35°C), Accuracy: ± 1°F (0.5°C)    
Humidity
Range: 10-90% Accuracy: ± 3% Typical
- X -
Motion
Sensor Type: PIR, quad, omnidirectional
Distance: 16.4 ft. (5 m)
Detection Range: 90 x 30 (HxV)
Movement Speed: 2.62 – 3.94 ft/s (0.8 – 1.2 m/s)
Detection Object: 15.75 x 9.84 in. (400 x 250 mm)
- X -
Inputs T1, 0 - Normally Open (NO) or Normally Closed (NC) dry contract, or 0-10 Vdc AI, or 50 kOhm thermistor @ 77°F (25°C)
A, B - Communication +/- (RS485)
In1, 0 - NO or NC dry contract, or 0-10 Vdc AI, or 50 kOhm thermistor @ 77°F (25°C)
C, R – Power 24 VAC
Outputs 11, 12, 13 – DO, 3A 14 – DO 0.3A 15, 16 - DO 0.3A or AO 0-10 Vdc, 5 mA max.,not isolated
Environmental Operating Range 50° to 122°F (10° to 50°C), 10 - 90% RH, non-condensing
Housing Square form factor, fire-retardant ABS plastic, UL94V-0
Mounting Installs to a standard wall box with mounting hardware included (consult technical instructions)
Compliance FCC CFR47, chapter 1, subchapter A, part 15, class B
ICC, ICES-003, class B
CE Mark LVD, 2014/35/EU
RoHS 2011/65/EU
C-Tick Mark, AS/NZS 61000-6-3
CA Prop. 65
  • Built-in temperature, humidity, and/or motion sensing for optimal control
  • Intuitive push-button interface with a clear LCD display
  • BACnet or MODBUS communication protocol capable (depending on model) for flexible system integration
  • Configurable inputs and outputs to support a variety of HVAC applications 
  • Real-time clock maintains accurate time for up to 7 days during power outages
  • Choice of 24VAC or 110-220V power supply for installation flexibility*

*Depending on thermostat model

  • Fan (FCUs): Enhance occupant comfort by providing individual control over fan speed and temperature
  • Rooftop Units (RTUs): Optimize RTU operation for energy efficiency through precise temperature and airflow control
  • Heat Pumps: Maximize heat pump performance and efficiency with integrated control of heating and cooling modes
  • Variable Frequency Drives (VFDs): Seamlessly integrate with VFDs to fine-tune motor speeds and optimize energy consumption

TB Series (BACnet)

Options 24 V, Temp. Only 24 V, Temp, Humidity, Motion 110-220V, Temp. Only
Branded TB-24-C TB-24-HM-C TB-C
Unbranded TB-24 TB-24-HM TB
Communication BACnet MS/TP (subordinate device) | Baud rates up to 76.8 kbps, detected and set automatically by the thermostat

TM Series (Modbus)

     
Options 24V, Temp., Humidity - 110 - 220V, Temp. Only
Unbranded TM-24 - TM
Communications Modbus RTU (server) | Baud rates up to 76.8 kbps, detected and set automatically by the thermostat
Power Requirements 24 VAC ± 15% 4VA no load, 76 VA Full Load 110-220 VAC
Display LCD
SENSING ELEMENT      
Temperature Range: 41-95° (5-35°C), Accuracy: ± 1°F (0.5°C)    
Humidity
Range: 10-90% Accuracy: ± 3% Typical
- X -
Motion
Sensor Type: PIR, quad, omnidirectional
Distance: 16.4 ft. (5 m)
Detection Range: 90 x 30 (HxV)
Movement Speed: 2.62 – 3.94 ft/s (0.8 – 1.2 m/s)
Detection Object: 15.75 x 9.84 in. (400 x 250 mm)
- X -
Inputs T1, 0 - Normally Open (NO) or Normally Closed (NC) dry contract, or 0-10 Vdc AI, or 50 kOhm thermistor @ 77°F (25°C)
A, B - Communication +/- (RS485)
In1, 0 - NO or NC dry contract, or 0-10 Vdc AI, or 50 kOhm thermistor @ 77°F (25°C)
C, R – Power 24 VAC
Outputs 11, 12, 13 – DO, 3A 14 – DO 0.3A 15, 16 - DO 0.3A or AO 0-10 Vdc, 5 mA max.,not isolated
Environmental Operating Range 50° to 122°F (10° to 50°C), 10 - 90% RH, non-condensing
Housing Square form factor, fire-retardant ABS plastic, UL94V-0
Mounting Installs to a standard wall box with mounting hardware included (consult technical instructions)
Compliance FCC CFR47, chapter 1, subchapter A, part 15, class B
ICC, ICES-003, class B
CE Mark LVD, 2014/35/EU
RoHS 2011/65/EU
C-Tick Mark, AS/NZS 61000-6-3
CA Prop. 65