WeatherMaster® Single-Packaged Rooftop Units with EcoBlue™ Technology
50GCQ

High Efficient Heat Pump Units with Puron® (R-410A) Refrigerant

3 to 5 Nominal Tons

Patented, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The industry’s first beltless direct-drive vane axial fan for rooftop units is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors and more – all available on this multi efficiency offering.


carrier-AHRI-210-240-Unitary-Small-AC-C
carrier-AHRI-210-240-Unitary-Small-AC
carrier-ASHRAE-90-1-certification
carrier-c-ul-us

Performance Features

  • Meets and exceeds ASHRAE 90.1 energy efficiency levels
  • New unit control board with intuitive quick fan speed adjustment
  • New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
  • Two-stage cooling capacity control on all models
  • SEERs to 16.2
  • HSPF to 8.3
  • Standard Cooling operating range up to 125 °F (52°C) and down to 35°F (2°C), lower temperature operation possible with low ambient kits
  • Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Proven high performance round copper tube and aluminum fin coil designs
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
  • All models use a TXV refrigerant metering device

Maintenance Features

  • New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as prior Carrier models for that original fit; reduces installation costs and time
  • Field convertible from vertical to horizontal airflow configuration
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point electrical and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated direct-drive ECM evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Precisely sizes suction line accumulator
  • Proven Time/Temperature defrost logo and control board

Standard Limited Warranty

  • 5 years electric heaters
  • 5 years parts only compressor
  • 3 year SystemVu™ controller
  • One year parts only on all other parts
  • Additional extended warranty packages available

Factory-Installed Options

  • Temperature Sensing EconoMi$er with built-in relief
  • Enthalpy Sensing EconoMi$er with built-in relief
  • Multiple Electric Heat Sizes & Voltages
  • Return Air Smoke Detector
  • Supply Air Smoke Detector
  • CO2 Sensor
  • Condensate Overflow Protection
  • Multiple Static Fan Capabilities
  • Phase Monitor/Protection
  • Thru-The-Base Utility Connections
  • Louvered Hail Guards
  • Non-Fused Disconnect Switch
  • MERV-8 Return Air Filters
  • Hinged Access Panels
  • Unpowered Convenience Outlet
  • Powered Convenience Outlet
  • Coated Coils:
    • Pre-Coat
    • E-Coat
    • Copper/Copper
  • Electrical Mechanical Controls
  • Intelligent SystemVu™ Integrated Communicating Controls
    • Large full text – multi line display
    • USB Flash Port for data transfer
    • Built in i-Vu®, CCN and BACnet®
    • Refrigerant pressure from display
    • Quick LED Status – Run, Alert, Fault
    • Conventional stat or sensor capabilities
    • Historical component runtime and starts
    • Supply Air Tempering
    • Equipment / System Touch Compatibility
    • Demand Limiting and ZS Sensor Compatibility
  • RTU-Open Communicating Controls
  • Extended Warranty Protection Plans
  • Financing Available

Heat Pump Models (50GCQ)

Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER)
Dimensions (in) LxWxH At 47°F At 17°F Approx. Unit Weight (lbs)
Heating Capacity (Btuh) HSPF
Heating Capacity (Btuh) HSPF
3 2 (16.2) 74 x 47 x 33 34000 8.3 17600 n/a 475
4 74 x 47 x 41 45500 24400 590
5 55500 30000 596

AHRI = Air-Conditioning, Heating & Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
IEER = Integrated Energy Efficiency Ratio
SEER = Seasonal Energy Efficiency Ratio
HSPF = Heating Seasonal Performance Factor

NOTES
1. Rated and certified under ARI Standard 210/240 3-5 ton.
2. Ratings are based on:
» Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.
3. All 50GCQ units comply with ASHRAE 90.1-2016 Energy Standard for minimum SEER and EER requirements.
4. 50GCQ units comply with US Energy Policy Act (2005).

Performance Features

  • Meets and exceeds ASHRAE 90.1 energy efficiency levels
  • New unit control board with intuitive quick fan speed adjustment
  • New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
  • Two-stage cooling capacity control on all models
  • SEERs to 16.2
  • HSPF to 8.3
  • Standard Cooling operating range up to 125 °F (52°C) and down to 35°F (2°C), lower temperature operation possible with low ambient kits
  • Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Proven high performance round copper tube and aluminum fin coil designs
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
  • All models use a TXV refrigerant metering device

Maintenance Features

  • New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as prior Carrier models for that original fit; reduces installation costs and time
  • Field convertible from vertical to horizontal airflow configuration
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point electrical and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated direct-drive ECM evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Precisely sizes suction line accumulator
  • Proven Time/Temperature defrost logo and control board

Standard Limited Warranty

  • 5 years electric heaters
  • 5 years parts only compressor
  • 3 year SystemVu™ controller
  • One year parts only on all other parts
  • Additional extended warranty packages available

Factory-Installed Options

  • Temperature Sensing EconoMi$er with built-in relief
  • Enthalpy Sensing EconoMi$er with built-in relief
  • Multiple Electric Heat Sizes & Voltages
  • Return Air Smoke Detector
  • Supply Air Smoke Detector
  • CO2 Sensor
  • Condensate Overflow Protection
  • Multiple Static Fan Capabilities
  • Phase Monitor/Protection
  • Thru-The-Base Utility Connections
  • Louvered Hail Guards
  • Non-Fused Disconnect Switch
  • MERV-8 Return Air Filters
  • Hinged Access Panels
  • Unpowered Convenience Outlet
  • Powered Convenience Outlet
  • Coated Coils:
    • Pre-Coat
    • E-Coat
    • Copper/Copper
  • Electrical Mechanical Controls
  • Intelligent SystemVu™ Integrated Communicating Controls
    • Large full text – multi line display
    • USB Flash Port for data transfer
    • Built in i-Vu®, CCN and BACnet®
    • Refrigerant pressure from display
    • Quick LED Status – Run, Alert, Fault
    • Conventional stat or sensor capabilities
    • Historical component runtime and starts
    • Supply Air Tempering
    • Equipment / System Touch Compatibility
    • Demand Limiting and ZS Sensor Compatibility
  • RTU-Open Communicating Controls
  • Extended Warranty Protection Plans
  • Financing Available

Heat Pump Models (50GCQ)

Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER)
Dimensions (in) LxWxH At 47°F At 17°F Approx. Unit Weight (lbs)
Heating Capacity (Btuh) HSPF
Heating Capacity (Btuh) HSPF
3 2 (16.2) 74 x 47 x 33 34000 8.3 17600 n/a 475
4 74 x 47 x 41 45500 24400 590
5 55500 30000 596

AHRI = Air-Conditioning, Heating & Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
IEER = Integrated Energy Efficiency Ratio
SEER = Seasonal Energy Efficiency Ratio
HSPF = Heating Seasonal Performance Factor

NOTES
1. Rated and certified under ARI Standard 210/240 3-5 ton.
2. Ratings are based on:
» Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.
3. All 50GCQ units comply with ASHRAE 90.1-2016 Energy Standard for minimum SEER and EER requirements.
4. 50GCQ units comply with US Energy Policy Act (2005).

carrier-dealer-design-2020-silver-logo
Carrier receives a Dealer Design Award for its Rooftop Units with EcoBlue™ Technology
carrier-buildings-logo-award-winner-2019
Award-Winning Savings
carrier-ecoblue-poy-award-logo-cutaway-rtu
RTUs with EcoBlue™ Technology win Silver in C-SE 'Product of the Year' competition
carrier-ecoblue-rtu-features-w-tc
Features and Benefits: Weather Series RTUs with EcoBlue™ Technology