Skip to main content

24/7 Commercial Service

call 1-800-379-6484

Find an expert

Gemini® Single-Stage Commercial Split-System
38AUZ

with Puron® Refrigerant

6 to 20 Tons

The Gemini® 38AU series outdoor units and matched with the 40RU series indoor air handlers offer a wide variety of options for your HVAC application needs. This series is designed for long dependable operation whether it's a rooftop or on-the-ground installation. All GEMINI 38AU Condensing Units and 40RU Fan Coils use environmentally sound Puron® refrigerant. Together, they create a reliable split system that provides easy solutions to a wide range of commercial HVAC needs.


carrier-AHRI-340-360-Unitary-Large-AC
carrier-intertek-ETL-listed-C-US
carrier-c-ul-us

Performance Features

  • 38AUZ single circuit cooling only System EERs from 11.5
  • ASHRAE 90.1 Efficiency Compliant
  • Standard crankcase heater
  • Compressor vibration isolation
  • Low ambient temperature control
  • Unit performance certified in accordance with ARI standard 340/360

Reliability Features

  • High and low-pressure switches
  • Anti-short cycling protection
  • Prepainted, galvanized steel cabinets that passes 500-hour salt-spray test
  • Compressor overload protection
  • Scroll compressor
  • E-Coat coil protection
  • UL, UL, Canada or ETL approved

Installation Features

  • Shipped with Puron (R-410A) refrigerant partial charge
  • Single-piece design
  • Perimeter base rail with forklift slots and lifting holes facilitates rigging
  • Suitable for mounting on the ground or the rooftop
  • 24V control circuit transformer permits quick, easy wiring of thermostats

Maintenance Features

  • Comfort Alert™ diagnostic board
  • Powered and non-powered 115-v convenience outlet
  • Compressor access panel with easy grip handle
  • Easy starting, no-strip screw feature
  • Non-fused disconnect switch

Standard Limited Warranty

  • 5 years parts only on compressor
  • One yar parts only on all other parts

Factory-Installed Options

  • Non-fused Disconnect
  • Premium, E-coated condenser coil
  • Convenience outlet (powered)
  • Low ambient temperature Motormaster® control
  • Louvered hail guards

Field-Installed Accessories

  • Low ambient temperature Motormaster® control
  • Louvered hail guard
  • Programmable thermostats

38AUZ/40RUA AHRI Cooling Ratings

Unit Cooling Stages Nominal Capacity (Tons) Net Cooling Capacity (MBH) Total Power (kW) EER IEER
38AUZ07/40RUA07 1 6 71 6.2 11.5 12.2
38AUZ08/40RUA08 1 7.5 92 8.2 11.2 11.8
38AUZ12/40RUA12 1 10 117 10.4 10.3 12.0
38AUZ14/40RUA14 1 12.5 148 13.5 11.0 12.0
38AUZ16/40RUA16 2 15 184 16.4 11.2 13.2
38AUZ25/40RUA25 2 20 240 21.8 11.0 11.2

AHRI = Air-Conditioning, Heating and Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
EER = Energy Efficiency Ratio
IEER = Integrated Energy Efficiency Ratio
COP = Coefficient of Performance

NOTES
1. Rated in accordance with ARI Standard 340/360---07, as appropriate.
2. Ratings are based on:
- Cooling Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 35°C (95°F) db outdoor air temp.
- IEER Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 4 various outdoor temperatures.
3. All units comply with ASHRAE 90.1 Energy Standard for minimum EER and IEER requirements.

Performance Features

  • 38AUZ single circuit cooling only System EERs from 11.5
  • ASHRAE 90.1 Efficiency Compliant
  • Standard crankcase heater
  • Compressor vibration isolation
  • Low ambient temperature control
  • Unit performance certified in accordance with ARI standard 340/360

Reliability Features

  • High and low-pressure switches
  • Anti-short cycling protection
  • Prepainted, galvanized steel cabinets that passes 500-hour salt-spray test
  • Compressor overload protection
  • Scroll compressor
  • E-Coat coil protection
  • UL, UL, Canada or ETL approved

Installation Features

  • Shipped with Puron (R-410A) refrigerant partial charge
  • Single-piece design
  • Perimeter base rail with forklift slots and lifting holes facilitates rigging
  • Suitable for mounting on the ground or the rooftop
  • 24V control circuit transformer permits quick, easy wiring of thermostats

Maintenance Features

  • Comfort Alert™ diagnostic board
  • Powered and non-powered 115-v convenience outlet
  • Compressor access panel with easy grip handle
  • Easy starting, no-strip screw feature
  • Non-fused disconnect switch

Standard Limited Warranty

  • 5 years parts only on compressor
  • One yar parts only on all other parts

Factory-Installed Options

  • Non-fused Disconnect
  • Premium, E-coated condenser coil
  • Convenience outlet (powered)
  • Low ambient temperature Motormaster® control
  • Louvered hail guards

Field-Installed Accessories

  • Low ambient temperature Motormaster® control
  • Louvered hail guard
  • Programmable thermostats

38AUZ/40RUA AHRI Cooling Ratings

Unit Cooling Stages Nominal Capacity (Tons) Net Cooling Capacity (MBH) Total Power (kW) EER IEER
38AUZ07/40RUA07 1 6 71 6.2 11.5 12.2
38AUZ08/40RUA08 1 7.5 92 8.2 11.2 11.8
38AUZ12/40RUA12 1 10 117 10.4 10.3 12.0
38AUZ14/40RUA14 1 12.5 148 13.5 11.0 12.0
38AUZ16/40RUA16 2 15 184 16.4 11.2 13.2
38AUZ25/40RUA25 2 20 240 21.8 11.0 11.2

AHRI = Air-Conditioning, Heating and Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
EER = Energy Efficiency Ratio
IEER = Integrated Energy Efficiency Ratio
COP = Coefficient of Performance

NOTES
1. Rated in accordance with ARI Standard 340/360---07, as appropriate.
2. Ratings are based on:
- Cooling Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 35°C (95°F) db outdoor air temp.
- IEER Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 4 various outdoor temperatures.
3. All units comply with ASHRAE 90.1 Energy Standard for minimum EER and IEER requirements.