Skip to main content

38APS

Air-Cooled Condensing Unit
Scroll compressors
Single-circuit
R410A
50/60Hz

Capacity range: 88~229 kW

  • Single circuit factory-installed option.
  • Highly efficient hermetic scroll compressor(s).
  • Combinations of condensing units with air handlers cover wide range of cooling solutions.
  • Low roof-load weight distribution and weatherproof construction enable rooftop or on-the-ground installations.
  • Commercial and industrial air conditioning applications.

Performance Features

  • Condensing unit EERs up to 12.4 and IPLV up to 18.4
  • Unit performance rated in accordance with AHRI Standard 365
  • Full capacity range single-circuit units (025-065 sizes)
  • Hermetic scroll compressors with option for digital compressor for superior part-load performance
  • Novation® microchannel heat exchanger (MCHX) condenser coils with option for E-coated Novation condenser coils
  • Compressor with neoprene isolators and oil heater(s)

Reliability Features

  • Galvanized steel cabinet, bonderized and finished with baked enamel, 500-hour salt-spray test
  • High and low-pressure protection
  • Compressor overload protection
  • Loss of charge and low suction superheat protection
  • Self contained 24-v CCN (Carrier Comfort Network) controls including transformer
  • Low ambient head pressure control
  • UL, CSA, and ETL approved

Maintenance Features

  • Oil-level sight glass, filter driers, liquid line solenoid valve
  • Access panel accessibility to compressor and control box
  • Compressor suction service valves and liquid shutoff valves

Installation Features

  • Shipped with nitrogen holding charge
  • On-the-ground or rooftop installation
  • 24V control circuit transformer permits quick, easy wiring of thermostats

Standard Warranty

  • One-year parts only compressor
  • One-year parts only on all other parts
  • Extended warranty packages available

Factory-Installed Options

  • Novation® microchannel heat exchanger (MCHX) coils:
    • Non-coated
    • E-coated
  • Single-circuit (sizes 025-065)
  • Non-fused disconnect
  • Low sound fans
  • Long line length check valves
  • High interrupt
  • Motormaster® V low ambient control
  • ComfortLink controls with scrolling marquee display module
  • Energy management module
  • Digital compressor

Field-Installed Accessories

  • Long line length check valves
  • Energy management module
  • Navigator display
  • TouchPilot display
  • BACnet translator control
  • LON translator control

Capacity Ratings

Size 60Hz 50Hz
Capacity (Nominal Tons) Capacity (Nominal kW) EER IPLV Capacity (Nominal Tons) Capacity (Nominal kW) EER IPLV
025 24.0 84.3 11.0 14.4 20.0 70.3 11.6 16.4
027 26.6 93.4 10.9 14.7 22.2 78.1 11.7 16.6
030 31.1 109.2 10.8 14.3 26.0 91.4 11.5 15.9
040 39.8 139.8 11.5 16.2 32.8 115.3 12.4 18.4
050 48.1 168.9 10.8 15.0 39.5 138.9 11.8 16.7
065 59.6 209.6 11.1 15.1 49.4 173.7 11.5 17.0

LEGEND
EER = Energy Efficiency Ratio IPLV = Integrated Part Load Value

NOTES
1. Unit performance is rated in accordance with ARI (Air Conditioning and Refrigeration Institute) Standard 365.
2. Ratings are based on 45°F (7.2°C) saturated suction temperature and 95°F (35°C) outside-air temperature, and include suction line losses.

Weights and Dimensions (Single Circuit)

Size Operating Weight (lbs) Dimensions (in)
Length Width Height
025 1077 88.24 40.34 61.0
027 1240 88.24 40.34 73.1
030 1246 88.24 40.34 73.1
040 1968 92.13 88.24 73.0
050 1977 92.13 88.24 73.0
065 2561 92.13 88.24 73.0

Performance Features

  • Condensing unit EERs up to 12.4 and IPLV up to 18.4
  • Unit performance rated in accordance with AHRI Standard 365
  • Full capacity range single-circuit units (025-065 sizes)
  • Hermetic scroll compressors with option for digital compressor for superior part-load performance
  • Novation® microchannel heat exchanger (MCHX) condenser coils with option for E-coated Novation condenser coils
  • Compressor with neoprene isolators and oil heater(s)

Reliability Features

  • Galvanized steel cabinet, bonderized and finished with baked enamel, 500-hour salt-spray test
  • High and low-pressure protection
  • Compressor overload protection
  • Loss of charge and low suction superheat protection
  • Self contained 24-v CCN (Carrier Comfort Network) controls including transformer
  • Low ambient head pressure control
  • UL, CSA, and ETL approved

Maintenance Features

  • Oil-level sight glass, filter driers, liquid line solenoid valve
  • Access panel accessibility to compressor and control box
  • Compressor suction service valves and liquid shutoff valves

Installation Features

  • Shipped with nitrogen holding charge
  • On-the-ground or rooftop installation
  • 24V control circuit transformer permits quick, easy wiring of thermostats

Standard Warranty

  • One-year parts only compressor
  • One-year parts only on all other parts
  • Extended warranty packages available

Factory-Installed Options

  • Novation® microchannel heat exchanger (MCHX) coils:
    • Non-coated
    • E-coated
  • Single-circuit (sizes 025-065)
  • Non-fused disconnect
  • Low sound fans
  • Long line length check valves
  • High interrupt
  • Motormaster® V low ambient control
  • ComfortLink controls with scrolling marquee display module
  • Energy management module
  • Digital compressor

Field-Installed Accessories

  • Long line length check valves
  • Energy management module
  • Navigator display
  • TouchPilot display
  • BACnet translator control
  • LON translator control

Capacity Ratings

Size 60Hz 50Hz
Capacity (Nominal Tons) Capacity (Nominal kW) EER IPLV Capacity (Nominal Tons) Capacity (Nominal kW) EER IPLV
025 24.0 84.3 11.0 14.4 20.0 70.3 11.6 16.4
027 26.6 93.4 10.9 14.7 22.2 78.1 11.7 16.6
030 31.1 109.2 10.8 14.3 26.0 91.4 11.5 15.9
040 39.8 139.8 11.5 16.2 32.8 115.3 12.4 18.4
050 48.1 168.9 10.8 15.0 39.5 138.9 11.8 16.7
065 59.6 209.6 11.1 15.1 49.4 173.7 11.5 17.0

LEGEND
EER = Energy Efficiency Ratio IPLV = Integrated Part Load Value

NOTES
1. Unit performance is rated in accordance with ARI (Air Conditioning and Refrigeration Institute) Standard 365.
2. Ratings are based on 45°F (7.2°C) saturated suction temperature and 95°F (35°C) outside-air temperature, and include suction line losses.

Weights and Dimensions (Single Circuit)

Size Operating Weight (lbs) Dimensions (in)
Length Width Height
025 1077 88.24 40.34 61.0
027 1240 88.24 40.34 73.1
030 1246 88.24 40.34 73.1
040 1968 92.13 88.24 73.0
050 1977 92.13 88.24 73.0
065 2561 92.13 88.24 73.0