AERO® Semi-Custom Central Station Air Handler
39M
1,500 to 60,500 Nominal Cfm
39MN - Indoor / 39MW - Outdoor
Carrier’s Aero 39M air handlers provide advanced technology and custom features in a streamlined, easy to install package. Indoor and outdoor units are available to handle a wide variety of applications. Units can be equipped with HEPA filters, stainless steel sloped drain pans, Agion® antimicrobial coating and other options. The 39M unit’s double-wall casing allows panels to be easily cleaned without damaging the insulation inside. Available fan options include forward-curved, airfoil, and plenum fans for extra quiet operation. Factory-installed controls maintain airflow and ventilation requirements while helping to prevent coil freeze-up, excessive humidity and poor indoor air quality (IAQ). Carrier’s AHUBuilder® software makes selecting and optimizing the 39M air handler easy.
Performance Features
- All units are shrink wrapped for complete protection while in transit
- Maximum deflection ratio of L/240 at 8 in. wg.
- Casing air leakage rate less than 1% at 8 in. wg. of unit nominal airflow
- Doublewall panel construction, insulation is sealed between the inner and outer panels
- Thermal break casing construction
- Optional factory mounted controls
- Chilled water, hot water, direct expansion (DX), electric and steam coils
- Tubular indirect fired gas furnace option with a minimum of 10:1 turndown
- Ultraviolet band C (UV-C) germicidal lamps
- Multiple filtration from pleated MERV 8 to HEPA filters
- Energy recovery ventilator (ERV) sections
- Multiple fan options
- Humidifiers for precise indoor climate conditioning
- Internal and external face and bypass damper sections
Reliability Features
- Optional 18 gauge exterior and/or interior skin
- Standard insulated, fully drainable, sloped drain pans in galvanized or stainless steel
Maintenance Features
- Optional prepainted and/or galvanized unit exterior
- Optional aluminum diamond treadplate floors
- All service may be performed through large, removable or hinged with lockable handle panels
- Marine lights and viewports for interior component inspection
Installation Features
- Units may be mounted in ceilings, closets, attics, etc.
- Variable frequency drives are programmed and started up at the factory
- Casing can be broken-down to individual panels and frame members
Factory-Installed Options
- Filter options from MERV 8 flat filters to face loaded HEPA filters
- Water coils
- Refrigerant coils
- Steam coils
- Electrical heat
- Tubular indirect fired gas furnaces
- Humidifiers
- Sound attenuators
- Energy recovery ventilator wheel (ERV) sections
Size | Nominal Airflow* (Cfm) | Dimensions (in)** | |
---|---|---|---|
Height*** | Width | ||
03W | 1500 | 37 | 33 |
06W | 3000 | 37 | 46 |
07T | 3500 | 60 | 39 |
08W | 4000 | 40 | 54 |
09T | 4500 | 57 | 42 |
10W | 5000 | 40 | 67 |
11T | 5500 | 66 | 45 |
12T | 6000 | 66 | 48 |
12W | 6000 | 47 | 67 |
14W | 7000 | 47 | 72 |
16T | 8000 | 75 | 51 |
17W | 8500 | 50 | 79 |
18T | 9000 | 78 | 54 |
21W | 10500 | 60 | 79 |
22T | 11000 | 84 | 60 |
25T | 12500 | 89 | 61 |
25W | 12500 | 60 | 86 |
30T | 15000 | 89 | 72 |
30W | 15000 | 60 | 104 |
35T | 17500 | 92 | 80 |
36W | 18000 | 71 | 109 |
37T | 18500 | 108 | 72 |
40W | 20000 | 77 | 109 |
42T | 21000 | 107 | 80 |
50W | 25000 | 87 | 117 |
51T | 25500 | 107 | 93.5 |
58T | 29000 | 120 | 93.5 |
61W | 30500 | 102 | 117 |
72W | 36000 | 113 | 120 |
85W | 42500 | 113 | 139 |
96W | 48000 | 126 | 139 |
110W | 55000 | 126 | 157 |
*Airflow is based upon 500ft/min face velocity.
**Airway length is dependent upon selected components. Check the product catalog for individual airway length of components.
***Unit height includes 6-in. base rail on an indoor unit. Other base rail height options are available.
Performance Features
- All units are shrink wrapped for complete protection while in transit
- Maximum deflection ratio of L/240 at 8 in. wg.
- Casing air leakage rate less than 1% at 8 in. wg. of unit nominal airflow
- Doublewall panel construction, insulation is sealed between the inner and outer panels
- Thermal break casing construction
- Optional factory mounted controls
- Chilled water, hot water, direct expansion (DX), electric and steam coils
- Tubular indirect fired gas furnace option with a minimum of 10:1 turndown
- Ultraviolet band C (UV-C) germicidal lamps
- Multiple filtration from pleated MERV 8 to HEPA filters
- Energy recovery ventilator (ERV) sections
- Multiple fan options
- Humidifiers for precise indoor climate conditioning
- Internal and external face and bypass damper sections
Reliability Features
- Optional 18 gauge exterior and/or interior skin
- Standard insulated, fully drainable, sloped drain pans in galvanized or stainless steel
Maintenance Features
- Optional prepainted and/or galvanized unit exterior
- Optional aluminum diamond treadplate floors
- All service may be performed through large, removable or hinged with lockable handle panels
- Marine lights and viewports for interior component inspection
Installation Features
- Units may be mounted in ceilings, closets, attics, etc.
- Variable frequency drives are programmed and started up at the factory
- Casing can be broken-down to individual panels and frame members
Factory-Installed Options
- Filter options from MERV 8 flat filters to face loaded HEPA filters
- Water coils
- Refrigerant coils
- Steam coils
- Electrical heat
- Tubular indirect fired gas furnaces
- Humidifiers
- Sound attenuators
- Energy recovery ventilator wheel (ERV) sections
Size | Nominal Airflow* (Cfm) | Dimensions (in)** | |
---|---|---|---|
Height*** | Width | ||
03W | 1500 | 37 | 33 |
06W | 3000 | 37 | 46 |
07T | 3500 | 60 | 39 |
08W | 4000 | 40 | 54 |
09T | 4500 | 57 | 42 |
10W | 5000 | 40 | 67 |
11T | 5500 | 66 | 45 |
12T | 6000 | 66 | 48 |
12W | 6000 | 47 | 67 |
14W | 7000 | 47 | 72 |
16T | 8000 | 75 | 51 |
17W | 8500 | 50 | 79 |
18T | 9000 | 78 | 54 |
21W | 10500 | 60 | 79 |
22T | 11000 | 84 | 60 |
25T | 12500 | 89 | 61 |
25W | 12500 | 60 | 86 |
30T | 15000 | 89 | 72 |
30W | 15000 | 60 | 104 |
35T | 17500 | 92 | 80 |
36W | 18000 | 71 | 109 |
37T | 18500 | 108 | 72 |
40W | 20000 | 77 | 109 |
42T | 21000 | 107 | 80 |
50W | 25000 | 87 | 117 |
51T | 25500 | 107 | 93.5 |
58T | 29000 | 120 | 93.5 |
61W | 30500 | 102 | 117 |
72W | 36000 | 113 | 120 |
85W | 42500 | 113 | 139 |
96W | 48000 | 126 | 139 |
110W | 55000 | 126 | 157 |